10W Single group rail type
10W Single group rail type (size:22.5 x 90 x 100mm)
Model Number |
Output |
Tol |
R&N |
Effi |
Power |
MDR-10-5 |
5V, 0〜2.0A |
± 2% |
80mV |
77% |
10W |
MDR-10-12 |
12V, 0〜0.84A |
± 1% |
120mV |
80% |
10W |
MDR-10-15 |
15V, 0〜0.67A |
± 1% |
120mV |
81% |
10W |
MDR-10-24 |
24V, 0〜0.42A |
± 1% |
150mV |
84% |
10W |
Universal input/ Full range |
|||||
Installed on Din Rail TS35/7 5 or 15 |
|||||
Protections: Short circuit /Over voltage/Over load |
|||||
Approvals:CE |
|||||
LED showing the work of state |
|||||
Cooling by free air convection |
|||||
100% full load burn-in test |
|||||
2 years warranty |
|||||
AC input voltage range:85~264VAC; 120~370VDC |
|||||
AC inrush current: Cold start, 35A at 115VAC,70Aat 230VAC |
|||||
Dc adjustment range:± 10% rated output voltage |
|||||
Overload: 105% to 150% shutdown current, automatically resume |
|||||
Over voltage protection :115% to 135% rated output voltage |
|||||
Withstand voltage:1/P-O/P:3KVAC,I/P-FG:1.5KVAC,O/P-FG:0.5KVAC |
|||||
Working temperature :-20℃~50℃(refer to output load derating curve) |
|||||
Connection: I/P:3poles, O/P:3 poles crew DIN terminal |
|||||
Packing :0.17Kg, 72PCS/13.2Kg/0.91CUFT |