Four Sets Of Switching Power Supply 120W
AC input selectable by switch
Protections:short circuit/overload/over voltage
Cooling by free air convection
100% full load burn-in test
Low cost,high reliability
2 year warranty
AC input voltage range: 85-132VAC, 170-264VAC, 47-63Hz,elected by switch
AC inrush current:Cold start,15A/115V,30A/230VAC
DC adjustment range: 士10%
Over load protection:105-150% fold back current limiting,auto-recovery
Over voltage protection:115%-135%rated output voltage
Setup,rise,hold up time:200ms,100ms,30ms
Withstand voltage:I/P-O/P: 1.5KVAC,I/P-FG:0.5KVAC,1 minute
Working temperature:10℃一+60℃, 20 % -90 %RH
Safety standards:Design refer to UI1012
EMC standards:Design refer to FCC part 15
Conneciton:8P/9.5mmpitch terminal block
Packing:0.91kg,20pcs/19.2kg/1.4CUFT
Model Number |
Output |
Tol |
RCN |
Effi |
Power |
|
5V.2.0-11.0A |
± 2% |
80mV |
|
|
Q-120A |
12V,0.5~4.0A |
± 6% |
120mV |
77% |
120W |
-5V,0.2~1.0A |
± 6% |
80mV |
|||
|
-12V.0.2-1.0A |
± 6% |
120mV |
|
|
|
5V.2.0-12.0A |
± 2% |
80mV |
|
|
Q-120B |
15V,0.5~3.0A |
土 10,-5% |
150mV |
76% |
122W |
-5V,0.2~1.0A |
± 6% |
80mV |
|||
|
-15V.0.2〜1.0A |
土 10,-5% |
150mV |
|
|
|
5V,2.0~12A |
± 2% |
80mV |
|
|
Q-120C |
12V.0.2-2.0A |
± 6% |
120mV |
80% |
124W |
24V.0.2-2.0A |
± 6% |
180mV |
|||
|
-12V.0.2-1.0A |
± 6% |
120mV |
|
|