Four Sets Of Switching Power Supply 60W
AC input selectable by switch
Protections:short circuit/overload/over voltage
Cooling by free air convection
100% full load burn-in test
Low cost,high reliability
2 year warranty
AC input voltage range: 85-264VAC, 47-63Hz,120-370VDC
AC inrush current:Cold start,15A/115V,30A/230VAC
DC adjustment range: 士10%
Over load protection:105-150% fold back current limiting,auto-recovery
Over voltage protection:115%-135%rated output voltage
Setup,rise,hold up time:800ms,200ms,60ms
Withstand voltage:I/P-O/P: 1.5KVAC,I/P-FG:0.5KVAC,1 minute
Working temperature:10℃一+60℃, 20 % -90 %RH
Safety standards:Design refer to UI1012
EMC standards:Design refer to FCC part 15
Conneciton:5P/9.5mmpitch terminal block
Packing:0.56kg,30pcs/17.8kg/1.0CUFT
Model Number |
Output |
Tol |
RCN |
Effi |
PP |
Q-60A |
5V,0.5~5.0A |
± 2% |
100mV |
70% |
60W |
12V.0.1-3.0A |
± 6% |
120mV |
|||
-5V,0.0~1.0A |
土 5% |
100mV |
|||
-12V.0.0〜1.0A |
土 5% |
120mV |
|||
Q-60B |
5V,0.5~5.0A |
± 2% |
100mV |
72% |
60W |
15V,0.1~3.0A |
土 8,-4% |
120mV |
|||
-5V,0.0~1.0A |
土 5% |
100mV |
|||
-15V.0.0〜1.0A |
土 5% |
120mV |
|||
Q60C |
5V,0.5~5.0A |
± 2% |
100mV |
75% |
62W |
12V.0.1-3.0A |
± 6% |
120mV |
|||
24V,0.1~1.5A |
土 8,-4% |
150mV |
|||
-12V.0.0〜1.0A |
土 5% |
120mV |